Sr Nc | Check List | Permissible Limits |
1 | Entry gate and 2 gates if corner | The grating line under the gate |
2 | Height of ramp | Max 1′ from road crown at the center of gate and install 3 pipes of each 9″ dia under the ramp |
3 | Set Backs (Front, Rear) | 5’x5‘ (30×60) |
4 | Set Backs (Front, Rear) | 6’x6‘ (35×70) |
5 | Set Backs (Front, Side 1, Rear) | 10’x4’x5′ (40×80) |
6 | Set Backs (Front, Side 1×2, Rear) | 13’x5’x5’x8′ (50×90) |
7 | Porch area | With in half of the front setback |
8 | No. of Storeys Allowed | Basement + Ground + First |
9 | Plinth Level (30×60) | Max 3′-6″ from the front road centre |
10 | Plinth Level (35×70) | Max 3′-6″ from the front road centre |
11 | Plinth Level (50×90) | Max 4′-6″ from the front road centre |
12 | Height of building | Max 30′ (till 1st floor slab) |
13 | Total Height of building | Max 38′ (till mumty parapet wall) |
14 | Parapet wall height (except mumty) | Max 3′ (at ground and 1st floor) |
15 | Mumty Area (30×60) | Max 350 sft |
16 | Mumty Area (35×70) | Max 350 sft |
17 | Mumty Area (50×90) | Max 400 sft |
18 | Canopi height on the first floor | Max 5’ |
19 | Canopi height on the ground floor | Max 5’ |
20 | Mumty floor projections | Max 1′-6″ |
21 | Projections | Max 3′ |
22 | Projection at the side of the 5” setback | Max 2′-6″ |
23 | Underground water tank / Overhead water tank (30×60) | 400-500 gallons max |
24 | Underground water tank / Overhead water tank (35×70) | 600-1000 gallons max |
25 | Underground water tank / Overhead water tank (40×80) | 600-1000 gallons max |
26 | Underground water tank / Overhead water tank (50×90) | 700-1250 gallons max |
27 | Soakage Pit (10’x6’x5′) | As per the approved drawing |
28 | Rain Water Harvesting Tank | Minimum as per underground water tank |
29 | Services Plan | As per the approved drawing |
30 | Boundary Wall Height Max | 6′ DPC and 3′ Fence |
31 | Open to Sky | 50 sft min and 5′ width |