Entrance of Gulberg Greens, Islamabad.
21
Jun

Bylaws for Residential Houses Gulberg Residencia, Islamabad

We are listing the bylaws checklist for the residential houses in Gulberg Residencia, Islamabad. Gulberg Residencia is located in Gulberg Greens and is becoming one of the most sought-after societies in Islamabad.

gulberg greens on a rainy day

 

“Further detail must be seen via approved drawings and building and zoning bylaws Gulberg Greens and Gulberg Residencia Islamabad – 2012 (IBECHS)”

Sr Nc Check List Permissible Limits
1 Entry gate and 2 gates if corner The grating line under the gate
2 Height of ramp Max 1′ from road crown at the center of gate and install 3 pipes of each 9″ dia under the ramp
3 Set Backs (Front, Rear) 5’x5‘ (30×60)
4 Set Backs (Front, Rear) 6’x6‘ (35×70)
5 Set Backs (Front, Side 1, Rear) 10’x4’x5′ (40×80)
6 Set Backs (Front, Side 1×2, Rear) 13’x5’x5’x8′ (50×90)
7 Porch area With in half of the front setback
8 No. of Storeys Allowed Basement + Ground + First
9 Plinth Level (30×60) Max 3′-6″ from the front road centre
10 Plinth Level (35×70) Max 3′-6″ from the front road centre
11 Plinth Level (50×90) Max 4′-6″ from the front road centre
12 Height of building Max 30′ (till 1st floor slab)
13 Total Height of building Max 38′ (till mumty parapet wall)
14 Parapet wall height (except mumty) Max 3′ (at ground and 1st floor)
15 Mumty Area (30×60) Max 350 sft
16 Mumty Area (35×70) Max 350 sft
17 Mumty Area (50×90) Max 400 sft
18 Canopi height on the first floor Max 5’
19 Canopi height on the ground floor Max 5’
20 Mumty floor projections Max 1′-6″
21 Projections Max 3′
22 Projection at the side of the 5” setback Max 2′-6″
23 Underground water tank / Overhead water tank (30×60) 400-500 gallons max
24 Underground water tank / Overhead water tank (35×70) 600-1000 gallons max
25 Underground water tank / Overhead water tank (40×80) 600-1000 gallons max
26 Underground water tank / Overhead water tank (50×90) 700-1250 gallons max
27 Soakage Pit (10’x6’x5′) As per the approved drawing
28 Rain Water Harvesting Tank Minimum as per underground water tank
29 Services Plan As per the approved drawing
30 Boundary Wall Height Max 6′ DPC and 3′ Fence
31 Open to Sky 50 sft min and 5′ width

This is a checklist that you must ensure is reflected in your submission drawings that you get from your architect or architecture firm.

Gulberg Greens and Gulberg Residencia entrance through red bridge

If you want to read about bylaws what are they and other society bylaws then click here.